Specifications |
NJP-3800C type |
Maximum yield |
228000 grains/hour |
machine weight |
2200kg |
Machine volume |
1395×1180×2260mm (height with automatic powder feeder:2880mm) |
power supply |
380/220V 50Hz |
total power |
10.5kw |
Number of holes |
27 holes |
Vacuum |
63m³/h -0.04~-0.08MPa |
vacuuming |
24.5Kpa 210m³/h |
compressed air |
Air consumption 12m³/h Pressure 0.3~0.4MPa |
source of water |
Water flow 1000L/h 0.3~0.4Mpa |
water requirements |
The water ring vacuum pump and the water tank are recycled, and the water source can be connected externally |
working noise |
≤78dBA |
Working temperature |
21°C±3°C |
working relative humidity |
40-55% |
Capsule on chance |
Empty capsule ≥ 99.9% Full capsule ≥ 99.8% |
Adapt Capsules |
00#-5# capsule |
Loading accuracy |
Western medicine ±3% Traditional Chinese medicine ±4% |
Adapt to the filling range |
Powder, Granule, Pellet, Tablet |
special function |
Powder collector function |
Material |
316 stainless steel is used for parts in direct contact with medicines |
specification |
Fully sign cGMP requirements |

It adopts the disc valve feeding method and is equipped with a vibration device. It solves the problem that the traditional screw feeding device has no fluidity and often fails to feed powders with poor fluidity such as Chinese herbal medicines and proprietary Chinese medicines. Easy to disassemble, easy to replace and clean.
Driven by guide rail, it has high precision and long service life. The closed design effectively prevents waste capsules and dust from entering. Good stability, orderly seeding, and accurate direction adjustment.
Modular design is adopted, and the pin-type positioning of the filling holder is used. During production, there is no need to stop the machine to adjust the filling capacity, and it is convenient to replace different filling rods.

The slot-type lock capsule plate has flexible adjustability and can be fine-tuned at any time without adjusting the station pull rod. Purified compressed air and intermittent gas impingement technology are adopted. It solves the problem of powder sticking to the mold and improves the probability of capsule loading.
JP-3800C adopts an outside cam drive system, simple in structure, easy to maintain, and cost-effective.